Deflector Wind Tunnel (UGWK)
Basic Information
Name: | Deflector Wind Tunnel (UGWK) | |
Facility: | Chair for Turbomachinery and Flight Propulsion (TFA) | |
Partner: | Technische Universität Dresden (TUD) |
Short Description
Deflector Wind Tunnel is a continuously operating open wind tunnel in suction mode (Eiffel channel).
Description
Deflector Wind Tunnel (UGWK)
- continuously operating open wind tunnel in suction mode (Eiffel channel)
- low Mach number low turbulence of the inflow
- Investigation of turbine or compressor cascades
Link to Further Details
Points of Contact
Notes
Technische Daten
- Bauart: Eiffelkanal (Saugbetrieb) mit einstufigem Radialgebläse
- Messquerschnitt: 380 x 300 mm
- Machzahl: Ma = 0,3
- Antriebsmotor: 37 kW (regelbar zwischen 0..2600 U/min)
Images
Last Update
Last updated at: 26 January 2018 at 16:40:56