Dresden
Technology Portal

 
Your access to research infrastructure and know-how
de|en

Contact

web: http://www.peg-dresden.de/de_index.html
email: e-mail
phone: +49 (0)351 458-4488
fax: +49 (0)351 458-4336
postal address: Technische Universität Dresden (TUD) / University Hospital Carl Gustav Carus Dresden (UKD), Pulmonary Engineering Group (PEG), Fetscherstr. 74, 01307 Dresden, Germany
office address: Technische Universität Dresden (TUD) / University Hospital Carl Gustav Carus Dresden (UKD), Pulmonary Engineering Group (PEG), Fiedlerstrasse 42 (Haus 91/ Laborraum A.20.020), 01307 Dresden, Germany
partner: Technische Universität Dresden
partner: University Hospital Carl Gustav Carus Dresden

Expertise

Die Arbeitsgruppe beschäftigt sich hauptsächlich mit der Entwicklung und Evaluation innovativer Beatmungsformen, insbesondere im Rahmen der Therapie des akuten Lungenversagens (ALI/ARDS).

Experimentelle Forschungen am Klein- und Großtiermodel realisieren wir in unserem eigenständigen Operationstrakt des Medizinisch-Theoretischen-Zentrums (MTZ), klinische Studien hingegen in den Operationssälen und auf den Intensivstationen des Universitätsklinkums.

Ein weiterer Schwerpunkt liegt auf der ingenieurwissenschaftlichen Entwicklung neuer Tools zur Diagnostik und Modellierung des respiratorischen Systems. Die Aufgabe wird vor allem von unseren Ingenieuren wahrgenommen.

 

Forschung

- Mechanische Beatmung an Tiermodellen des ARDS

  • Kleintiere: Ratten, Kaninchen
  • Großtiere: Hausschwein

- Methoden

  • Zellkultur
  • Präparation von Nucleinsäuren und Proteinen (DNA, RNA)
  • Konventionelle und Real Time PCR
  • Western Blot
  • ELISA
  • Immunfluoreszenzmikroskopie
  • FACS (Fluorescence Activated Cell Sorter)
  • Histologie
  • Blutgasanalyse
  • Pulmonale Perfusionsmessung (Microspheres)

- Typen der Mechanischen Beatmung

  • Variable Druckunterstützte Beatmung (Dräger Evita XL and Dräger Infinity)
  • Variable Druck/Volume-kontrollierte Beatmung (Dräger Evita XL, Harvard Inspira ASVp)
  • Neurally adjust ventilator assist (Maquet Servo I)

 

***********English***********

Our group is interested in the development and evaluation of new and innovative forms of mechanical ventilation, with a focus on the therapy of acute lung failure (ALI/ARDS). We conduct research in large and small animal models at the Medical Theoretical Center (MTZ). Our clinical trials are undertaken in operating suites and intensive care units at the university hospital.

In addition, we are involved in the development of innovative tools for modeling and diagnosing the respiratory system. A number of highly skilled engineers provide us with technical expertise on this project.

 

Research

- Mechanical ventilation in animal models of ARDS

  • Small animals: rats, rabbits
  • Large animals: swine

- Methods

  • Cell cultures
  • Purification of nucleic acids (RNA, DNA) and proteins
  • Conventional and real-time PCR
  • Western blotting
  • ELISA
  • Immunofluorescence microscopy
  • FACS (Fluorescence Activated Cell Sorter)
  • Histology
  • Blood gas analysis
  • Pulmonary perfusion measurement (Microspheres)

Modes of mechanical ventilation

  • Variable pressure assist ventilation (Dräger Evita XL and Dräger Infinity)
  • Variable pressure/volume controlled ventilation (Dräger Evita XL, Harvard Inspira ASVp)
  • Neurally adjust ventilator assist (Maquet Servo I)

Affiliations

Parent Units

name type actions
Institute and Outpatient Clinics of Anesthesiology and Intensive Therapy (ANE) Clinic view

Last Update

Last updated at: 2019-03-13 10:41 CET